ProFe
ProH/HPS
OFG/285
TAFB
TwinDelta
MK02
Chamber



OFG-285 Over-filling Guard

The OFG-285 consists of a main unit with a safety circuit and a swing arm conduit to an electrode head. The main box can be mounted to brackets 50 mm (2") outside a launder. The electrode head is swung over the molten metal and leveled so that the ends of the electrodes hit just above the maximum allowed level in the launder.

Technical Specifications
Part number: 91001
Powerrequirement : 24 VDC +15%, 4 amps
Power consumption: < 2.8 W
Closure stainless steel: IP 66 / NEMA 4
Dimensions: Main box: 300x150x80 mm (11.81"x5.9"x3.15")
Electrode head: 100x100x80 mm (3.94"x3.94"x3.15")
Electrode length: 285 mm (11.22")
Digital output: Over-filling limit, interlocking relay contacts
Failure monitoring on connection to electrodes


Click here for datasheet in PDF format

For questions and/or sales inquiries please contact techinfo@precimeter.com or sales@precimeter.com