Furnace Tap Out

TXP-10

Increase quality and safety with Furnace tap out actuators. Stabilize the molten metal flow and control your launder levels.

Download Data Sheet
Here’s a caption for this image, it gives context to the image, and looks cool.

Product information

The Tap Out Actuator TXP-10 is primarily used to control the flow of molten metal launder at the exit tap hole of a stationary furnace. The TXP-10 can be mounted vertically with a special linkage arm system which has a stroke of 101 mm (4”).This actuator is also avaliable as the TXP-20 with a 20” stroke.

Furnace tap out control with TXP-10 Tap Out Actuator. The Precimeter TXP-10 actuator connected to the ProH and an MLC control panel form a system that accurately controls the molten metal level and flow out of the stationary furnace.

Advantages

Accurate control
Robust design
Easy installation
Minimal maintenance
Flexible mounting options
Available with two stroke lengths
Terminal connection for parameter settings
Ethernet protocol (optional)
Product features
Laser sensor type
CD2350R3000
CD1000R900
CD1150R400
CD180R200
CD900R750
CD450R300
CD450R300
CD1500R1600
CD800R1500
CD900R500
CD700R300
CD450R300
CD300R300
CD240R325
Clearance distance
2350 mm (92.5")
1000 mm (39.4")
1150 mm (45.3")
180 mm (7.1")
900 mm (35.4")
450 mm (17.7")
450 mm (17.7")
1500 mm (59.0")
800 mm (31.5")
900 mm (34.4")
700 mm (27.6")
450 mm (17.7")
300 mm (11.8")
240 mm (9.4")
Measurement range
3000 mm (118.1")
900 mm (35.4")
400 mm (15.8")
200 mm (7.9")
750 mm (29.5")
300 mm (11.8")
300 mm (11.8")
1600 mm (63.0")
1500 mm (59.0")
500 mm (19.7")
300 mm (11.8")
300 mm (11.8")
300 mm (11.8")
325 mm (12.8")
Resolution
0.74mm (0.029")
0.22mm (0.009")
0.1mm (0.004")
0.05mm (0.002")
+- 1mm (0.04")
0.074mm (0.03")
0.074mm (0.03")
0.39mm (0.016")
0.37mm (0.015")
0.122mm (0.005")
0.08mm (0.003")
0.08mm (0.003")
0.08mm (0.003")
0.08mm (0.003")
Technical specifications

TXP 10 - 1

Stroke:

TXP 10 - 2

Accuracy:

TXP 10 - 3

Closing Force:

TXP 10 - 4

Positioning:

TXP 10 - 5

Power Requirement:

TXP 10 - 6

Cooling:

TXP 10 - 7

Interface:

Operation Signals

TXP 10 - 8

Arm/Rod Position:

TXP 10 - 9

Calibration:

Feedback signals

TXP 10 - 10

Arm/Pin Position:

TXP 10 - 11

Internal Temp Output:

TXP 10 - 12

Ethernet Protocol:
32-254 mm (1.25”-10”)
±0.24 mm
1000N
Stepper motor
24 VDC < 1 A
Compressed air (1/4” connection)
Serial communication
-
4-20mA (0-100%)
24 VDC
-
4-20mA (0-100%)
4-20mA (0-100°C)
Optional (Profinet, Ethernet IP or Modbus TCP)
Options
No items found.
No items found.

Have questions?

Fill out the form below and we will get back to you as soon as possible.
By requesting information, I hereby agree to the Precimeter Privacy Policy.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
three men with hard hats on talking and laughing

Interested in our products?

Give us a call or send a message.